ORTEA
THREE-PHASE VOLTAGE STABILISERS |
| General Information: The
stabilising assembly is built to be connected between supply and loads. The purpose is to
supply a stabilised (within ±1%) voltage to the load, working with a variable input
voltage. The stabilisation is reached by means of electromechanical devices in the power
circuit and electronic devices in the control auxiliary circuit. |
|
The stabiliser can
operate with a load variation interval variable from 0 up to 100 % with minimum response
time. As the voltage regulation is obtained without chopping the voltage sine wave, the
user is not affected by harmonic distortion.
|
|
The equipment is set
in an IP21 protected metallic cubicle having variable dimensions accordingly to the power
size. |
|
For lower
ratings, the stabiliser is built with three single-phase units in three-phase connection.
Although the assembly is usually air cooled, for very high ratings the voltage regulator
can be put inside a tank and oil cooled. |
|
In case of heavy
environmental conditions, the stabiliser can be provided with forced ventilation. |
Main Parts Description: The main components of the equipment are: three-phase
"booster" transformer; motorized three-phase voltage regulator; auxiliary
circuit. |
| ORION
TYPE |
 |
|
The ORION
stabilisers cover the rating range between 5kVA and 105kVA and can be provided either with
independent voltage regulation on each phase or with voltage regulation based on the
average of the three-phase voltage. |
|
These stabilisers
allow for the choice between two different values of the input voltage variation (±15% o
±20%) by means of two different connections. |
|
The type with
independent voltage regulation on each phase are built up with three single-phase units in
three-phase connection. |
|
ORION THREE-PHAES VOLTAGE
STABILISER
| Type |
Rating
[ kVA ] |
Input
voltage
[ V ] |
Input
variation
[ % ] |
Output
voltage
[ V ] |
Output
variation
[ % ] |
Size
[ mm ] |
Weight
[ kg ] |
| A5-15 |
5 |
400 |
25 |
400 |
1 |
290x500x850 |
40 |
| Y5-15 |
3,6
5 |
400
400 |
20
15 |
400
400 |
1
1 |
290x500x850
290x500x850 |
55
55 |
| A10-15 |
7,5
10 |
400
400 |
20
15 |
400
400 |
1
1 |
290x500x850
290x500x850 |
50
50 |
| Y10-15 |
7,5
10 |
400
400 |
20
15 |
400
400 |
1
1 |
290x500x850
290x500x850 |
65
65 |
| A15-15 |
12
15 |
400
400 |
20
15 |
400
400 |
1
1 |
360x520x1000
360x520x1000 |
85
85 |
| Y15-15 |
12
15 |
400
400 |
20
15 |
400
400 |
1
1 |
360x520x1000
360x520x1000 |
100
100 |
| A20-15 |
15
20 |
400
400 |
20
15 |
400
400 |
1
1 |
360x520x1000
360x520x1000 |
105
105 |
| Y20-15 |
15
20 |
400
400 |
20
15 |
400
400 |
1
1 |
360x520x1000
360x520x1000 |
120
120 |
| A30-15 |
24
30 |
400
400 |
20
15 |
400
400 |
1
1 |
405x670x1150
405x670x1150 |
140
140 |
| Y30-15 |
24
30 |
400
400 |
20
15 |
400
400 |
1
1 |
405x670x1150
405x670x1150 |
160
160 |
| A50-15 |
36
50 |
400
400 |
20
15 |
400
400 |
1
1 |
405x670x1150
405x670x1150 |
160
160 |
| Y50-15 |
36
50 |
400
400 |
20
15 |
400
400 |
1
1 |
405x670x1150
405x670x1150 |
180
180 |
| A75-15 |
60
75 |
400
400 |
20
15 |
400
400 |
1
1 |
605x800x1600
605x800x1600 |
260
260 |
| Y75-15 |
60
75 |
400
400 |
20
15 |
400
400 |
1
1 |
605x800x1600
605x800x1600 |
350
350 |
| A105-15 |
80
105 |
400
400 |
20
15 |
400
400 |
1
1 |
605x800x1600
605x800x1600 |
400
400 |
| Y105-15 |
80
105 |
400
400 |
20
15 |
400
400 |
1
1 |
605x800x1600
605x800x1600 |
400
400 |
A =
regulation on the three-phase voltage
Y = independent regulation on each phase |
|
| Any of technical data of the
previous table can be altered either because of a company choice or because of a specific
request by the Customer. версия для печати |
| STY
/ STA TYPE |
 |
|
These stabilisers
have many constructive similarities, but they differ in the way in which they work on the
voltage to be stabilized. |
|
STA: voltage
regulation on the average of the three phases. The stabiliser has a simpler construction
and can be used mainly with three-phase loads. |
|
STY: the
stabilising effect is obtained operating independently on each phase. This solution is
therefore particularly useful with unbalanced three-phase loads or single-phase loads. For
proper operation, the presence of the neutral wire is necessary. . |
|
STY THREE-PHAES VOLTAGE STABILISER
| Type |
Rating
[ kVA ] |
Input
voltage
[ V ] |
Input
variation
[ % ] |
Output
voltage
[ V ] |
Output
variation
[ % ] |
Size
[ mm ] |
Weight
[ kg ] |
| 100-15 |
100 |
400 |
15 |
400 |
1 |
1000x800x1800 |
550 |
| 100-20 |
100 |
400 |
20 |
400 |
1 |
1000x800x1800 |
630 |
| 150-15 |
150 |
400 |
15 |
400 |
1 |
1000x800x1800 |
630 |
| 150-20 |
150 |
400 |
20 |
400 |
1 |
1400x800x1800 |
800 |
| 200-15 |
200 |
400 |
15 |
400 |
1 |
1400x800x1800 |
800 |
| 200-20 |
200 |
400 |
20 |
400 |
1 |
1400x800x1800 |
900 |
| 300-15 |
300 |
400 |
15 |
400 |
1 |
1400x800x1800 |
900 |
| 350-20 |
350 |
400 |
20 |
400 |
1 |
2300x800x1800 |
1400 |
| 450-15 |
450 |
400 |
15 |
400 |
1 |
2300x800x1800 |
1400 |
| 450-20 |
450 |
400 |
20 |
400 |
1 |
2300x800x1800 |
1650 |
| 600-15 |
600 |
400 |
15 |
400 |
1 |
2300x800x1800 |
1650 |
| 600-20 |
600 |
400 |
20 |
400 |
1 |
2600x1200x2007 |
2007 |
| 750-15 |
750 |
400 |
15 |
400 |
1 |
2600x1200x2007 |
2007 |
| 750-20 |
750 |
400 |
20 |
400 |
1 |
2600x1200x2007 |
2200 |
| 1000-15 |
1000 |
400 |
15 |
400 |
1 |
2600x1200x2007 |
2200 |
| 1000-20 |
1000 |
400 |
20 |
400 |
1 |
3000x1200x2200 |
2600 |
| 1500-15 |
1500 |
400 |
15 |
400 |
1 |
3000x1200x2200 |
2600 |
| 1500-20 |
1500 |
400 |
20 |
400 |
1 |
3000x1600x2200 |
4500 |
| 2007-15 |
2007 |
400 |
15 |
400 |
1 |
3000x1600x2200 |
4500 |
| 1750-20 |
1750 |
400 |
20 |
400 |
1 |
3500x1600x2200 |
5200 |
| 2500-15 |
2500 |
400 |
15 |
400 |
1 |
3500x1600x2200 |
5200 |
| 2007-20 |
2007 |
400 |
20 |
400 |
1 |
3500x1600x2200 |
5700 |
| 3000-15 |
3000 |
400 |
15 |
400 |
1 |
3500x1600x2200 |
5700 |
| 3500-20 |
3500 |
400 |
15 |
400 |
1 |
4000x1800x2200 |
6500 |
| 3000-15 |
3000 |
400 |
20 |
400 |
1 |
5000x2007x2200 |
7100 |
| 4000-20 |
4000 |
400 |
15 |
400 |
1 |
5000x2007x2200 |
7100 |
|
| Any of technical data of the
previous table can be altered either because of a company choice or because of a specific
request by the Customer. |
STA THREE-PHAES VOLTAGE STABILISER
| Type |
Rating
[ kVA ] |
Input
voltage
[ V ] |
Input
variation
[ % ] |
Output
voltage
[ V ] |
Output
variation
[ % ] |
Size
[ mm ] |
Weight
[ kg ] |
| 100-15 |
100 |
400 |
15 |
400 |
1 |
1000x800x1800 |
550 |
| 100-20 |
100 |
400 |
20 |
400 |
1 |
1000x800x1800 |
630 |
| 150-15 |
150 |
400 |
15 |
400 |
1 |
1000x800x1800 |
630 |
| 150-20 |
150 |
400 |
20 |
400 |
1 |
1400x800x1800 |
800 |
| 200-15 |
200 |
400 |
15 |
400 |
1 |
1400x800x1800 |
800 |
| 200-20 |
200 |
400 |
20 |
400 |
1 |
1400x800x1800 |
900 |
| 300-15 |
300 |
400 |
15 |
400 |
1 |
1400x800x1800 |
900 |
| 350-20 |
350 |
400 |
20 |
400 |
1 |
2300x800x1800 |
1400 |
| 450-15 |
450 |
400 |
15 |
400 |
1 |
2300x800x1800 |
1400 |
| 450-20 |
450 |
400 |
20 |
400 |
1 |
2300x800x1800 |
1650 |
| 600-15 |
600 |
400 |
15 |
400 |
1 |
2300x800x1800 |
1650 |
|
| Any of technical data of the
previous table can be altered either because of a company choice or because of a specific
request by the Customer. |
| AQUARIUS |
 |
|
They are provided
when minimum speed operation time is determinant (for example: computer). The AQUARIUS
three-phase electronic stabilisers adjust within ±3% of the nominal voltage, the output
voltage. The load is protected as for -18%/+14% input voltage variation as for short but
with high value peak (4KV) overvoltage. One input filter protects the load from harmonic
distortion on the electric network. |
|
AQUARIUS THREE-PHASE
VOLTAGE STABILISERS
| Type |
Rating
[ kVA ] |
Input
voltage
[ V ] |
Input
variation
[ % ] |
Output
voltage
[ V ] |
Output
variation
[ % ] |
Size
[ mm ] |
Weight
[ kg ] |
| E600 |
6 |
380/400/415 |
-18/+14 |
380/400/415 |
3 |
340x540x310 |
44 |
| E1000 |
10 |
380/400/415 |
-18/+14 |
380/400/415 |
3 |
340x540x310 |
48 |
| E1200 |
12 |
380/400/415 |
-18/+14 |
380/400/415 |
3 |
340x540x310 |
52 |
| E1500 |
15 |
380/400/415 |
-18/+14 |
380/400/415 |
3 |
340x540x310 |
60 |
|
| size="1">Any of technical data
of the previous table can be altered either because of a company choice or because of a
specific request by the Customer. |